RAK12001 WisBlock Fingerprint Sensor Module Installation Guide
WisBlock Module Installation
The RAK12001 is a fingerprint sensor module based on GROW R307. This module supports both fingerprint enrollment and fingerprint matching. For more information about RAK12001, refer to the Datasheet.
The RAK12001 module can be connected to the sensor slot of the WisBlock Base to communicate with the WisBlock Core. It can be mounted on double-size sensor slots with UART pins, such as slots A, E, & F (also on slot C with the RAK19003 Mini Base board). Also, always secure the connection of the WisBlock module by using compatible screws.
Figure 1: RAK12001 Connection to WisBlock BaseSelect a suitable WisBlock Base and WisBlock Core according to your application requirements and hardware configuration.
Assembling and Disassembling of WisBlock Modules
Assembling
The location for the sensor slots is properly marked by silkscreen. Follow carefully the procedure defined in WisBlock Base board assembly/disassembly instructions to attach a WisBlock module. Once attached, carefully fix the module with three pieces of M1.2 x 3 mm screws.
Figure 1: RAK12001 assembly to WisBlock BaseDisassembling
The procedure in disassembling any type of WisBlock modules is the same.
- First, remove the screws.
Figure 1: Removing screws from the WisBlock module- Once the screws are removed, check the silkscreen of the module to find the correct location where force can be applied.
Figure 1: Finding the proper position to detach the WisBlock module- Apply even force to the module at the position of the connector to detach the module from the WisBlock Base.
Figure 1: Applying even forces on the proper location of a WisBlock moduleIf you will connect other modules to the remaining WisBlock Base slots, check on the WisBlock Pin Mapper tool for possible conflicts.
After all this setup, you can now connect the battery (optional) and USB cable to start programming your WisBlock Core.
- Batteries can cause harm if not handled properly.
- Only 3.7-4.2 V Rechargeable LiPo batteries are supported. It is highly recommended not to use other types of batteries with the system unless you know what you are doing.
- If a non-rechargeable battery is used, it has to be unplugged first before connecting the USB cable to the USB port of the board to configure the device. Not doing so might damage the battery or cause a fire.
- Only 5 V solar panels are supported. Do not use 12 V solar panels. It will destroy the charging unit and eventually other electronic parts.
- Make sure the battery wires match the polarity on the WisBlock Base board. Not all batteries have the same wiring.