RAK12023 WisBlock Soil Moisture Sensor Connector Module Installation Guide
Prerequisite
The modules required before installation include:
- RAK12023 & RAK12035 WisBlock Soil Moisture Sensor Module
- Your choice of WisBlock Base with IO slot
- Your choice of WisBlock Core
WisBlock Module Installation
The RAK12023 extends the WisBlock system with soil moisture and soil temperature sensing capability. It connects the RAK12035 soil moisture sensor probe to the WisBlock system. The RAK12035 is a separate sensor probe that needs to be installed in the soil for measurement. Only one RAK12035 can be connected to the RAK12023 at a time.
Connect the RAK12023 to the IO slot on a WisBlock Base to communicate with the WisBlock Core, and secure the module with a compatible screw.
Figure 1: RAK12023 connection to WisBlock BaseSelect a suitable WisBlock Base and WisBlock Core according to your application requirements and hardware configuration.
RAK12035 Soil Moisture Sensor Probe
A separate sensor PCB module RAK12035 is required. The RAK12035 is a sensor probe that you need to bury into the soil to measure the moisture of the soil.
For more information about RAK12035, refer to the RAK12035 Soil Moisture Sensor Overview.
Figure 1: RAK12035 Soil Moisture SensorAssembling and Disassembling of WisBlock Modules
Assembling
The RAK12023 module can be mounted on the IO slot of the WisBlock Base board. Also, always secure the connection of the WisBlock module by using compatible screws.
Figure 1: RAK12023 mounting connection to WisBlock Base moduleDisassembling
The procedure in disassembling any type of WisBlock modules is the same.
- First, remove the screws.
Figure 1: Removing screws from the WisBlock module- Once the screws are removed, check the silkscreen of the module to find the correct location where force can be applied.
Figure 1: Finding the proper position to detach the WisBlock module- Apply even force to the module at the position of the connector to detach the module from the WisBlock Base.
Figure 1: Applying even forces on the proper location of a WisBlock moduleIf you will connect other modules to the remaining WisBlock Base slots, check on the WisBlock Pin Mapper tool for possible conflicts.
After all this setup, you can now connect the battery (optional) and USB cable to start programming your WisBlock Core.
- Batteries can cause harm if not handled properly.
- Only 3.7-4.2 V Rechargeable LiPo batteries are supported. It is highly recommended not to use other types of batteries with the system unless you know what you are doing.
- If a non-rechargeable battery is used, it has to be unplugged first before connecting the USB cable to the USB port of the board to configure the device. Not doing so might damage the battery or cause a fire.
- Only 5 V solar panels are supported. Do not use 12 V solar panels. It will destroy the charging unit and eventually other electronic parts.
- Make sure the battery wires match the polarity on the WisBlock Base board. Not all batteries have the same wiring.