RAK12047 WisBlock VOC Sensor Module Installation Guide
Prerequisite
The modules required before installation include:
- RAK12047 WisBlock VOC Sensor Module
- Your choice of WisBlock Base
- Your choice of WisBlock Core
WisBlock Module Installation
The RAK12047 extends the WisBlock system with air quality monitoring capability. Connect it to Sensor Slot A through F on a WisBlock Base to communicate with the WisBlock Core, and secure the module with a compatible screw.
Figure 1: RAK12047 connection to WisBlock BaseSelect a suitable WisBlock Base and WisBlock Core according to your application requirements and hardware configuration.
Assembling and Disassembling of WisBlock Modules
Assembling
The location for Slot A, B, C, D, E, and F are properly marked by silkscreen. Slots C and D are located on the bottom of WisBlock Base. Follow carefully the procedure defined in WisBlock Base board assembly/disassembly instructions to attach a WisBlock module. Once attached, carefully fix the module with an M1.2 x 3 mm screw.
Figure 1: RAK12047 connection to WisBlock BaseDisassembling
The procedure in disassembling any type of WisBlock modules is the same.
- First, remove the screws.
Figure 1: Removing screws from the WisBlock module- Once the screws are removed, check the silkscreen of the module to find the correct location where force can be applied.
Figure 1: Finding the proper position to detach the WisBlock module- Apply even force to the module at the position of the connector to detach the module from the WisBlock Base.
Figure 1: Applying even forces on the proper location of a WisBlock moduleIf you will connect other modules to the remaining WisBlock Base slots, check on the WisBlock Pin Mapper tool for possible conflicts.
After all this setup, you can now connect the battery (optional) and USB cable to start programming your WisBlock Core.
- Batteries can cause harm if not handled properly.
- Only 3.7-4.2 V Rechargeable LiPo batteries are supported. It is highly recommended not to use other types of batteries with the system unless you know what you are doing.
- If a non-rechargeable battery is used, it has to be unplugged first before connecting the USB cable to the USB port of the board to configure the device. Not doing so might damage the battery or cause a fire.
- Only 5 V solar panels are supported. Do not use 12 V solar panels. It will destroy the charging unit and eventually other electronic parts.
- Make sure the battery wires match the polarity on the WisBlock Base board. Not all batteries have the same wiring.