WisBlock Unify Outdoor Enclosure 150x100x45 with Solar Panel Installation Guide
Package Contents
Figure 1: Medium WisBlock Unify Enclosure package content| Number | Name | Quantity | Material | Color |
|---|---|---|---|---|
| 1 | Top Cover with Solar Panel | 1 | ABS UL94V-0 | Cool Gray or White |
| 2 | Bottom Base | 1 | ABS UL94V-0 | Cool Gray or White |
| 3 | Gasket | 1 | Silicone | Black |
| 4 | Screw | 4-6 | Stainless steel |
Assembly Guide
1. Prepare the Lid and Gasket
Install the rubber gasket in the groove of the top cover, as shown in Figure 2. Put the four corners of the gasket into the groove, and then press the middle gently. Ensure that the gasket is not twisted.
Before assembly, ensure that the gasket is installed correctly. The rubber gasket helps seal the enclosure properly and protects it from dust and water.
Figure 1: Installing the rubber gasket2. Choose the Internal Mounting Plate
Prepare the mounting plate. The following are the two types of internal mounting plates:
- Plain mounting plate
- WisBlock bespoke mounting plate
Plain Mounting Plate
The plain mounting plate features holes solely for mounting the enclosure. It is designed to be customized depending on the circuit board to be placed in the enclosure.
Figure 1: Plain mounting plateWisBlock Bespoke Mounting Plate
The WisBlock Bespoke Mounting Plate is designed specifically to hold WisBlock Base boards. You have to cut the excess parts using a wire cutter depending on the WisBlock Base board that you have.
The following are cutting guides indicating what should be cut based on the WisBlock Base board.
For the cutting reference, the red line is the cut-out area.
Figure 1: Cutting-out excess parts of the WisBlock Internal mounting plateRAK5005-O
Figure 1: RAK5005-O WisBlock Base board cut-out areaRAK19007
Figure 1: RAK19007 WisBlock Base board cut-out areaRAK19003
Figure 1: RAK19003 WisBlock Base board cut-out areaRAK19001
Figure 1: RAK19001 WisBlock Base board cut-out area3. Screw the WisBlock to Internal Mounting Plate
After cutting the Internal Mounting Plate, install the WisBlock Base board onto the Internal Mounting Plate with 2.2*5 mm self-tapping screws, as shown in Figure 9.
Figure 1: Installing WisBlock Base board on the Internal Mounting Plate4. Attach the Mounting Plate to the Enclosure
Install the WisBlock Internal Mounting Plate to the base of the enclosure using four (4) pieces of M3*4 mm Countersunk head screws, as shown in Figure 10.
Figure 1: Installing Internal Mounting Plate to the enclosure5. Cover the Enclosure with a Lid
Close the WisBlock Unify Enclosure with the top lid using four pieces of M3*8 mm head screw with a washer, as shown in Figure 11.
Make sure that the solar panel wire will not be squeezed by the gasket and is properly arranged inside the enclosure with the other parts inside like the circuit board, stand-offs, screws, etc.
Figure 1: Closing the WisBlock Unify EnclosureMounting Guide
After full assembly of the enclosure, the next step is to choose the right mounting accessory for your application. Each mount accessory has a mark indicated by a capital letter, as shown in Figure 11, and each WisBlock Unify Enclosure has several fixed positions, which are indicated by a mark of numerals, as shown in Figure 13. The medium-sized WisBlock Unify Enclosure has only four (4) fixed positions.
Figure 1: Mount accessories marked with letters
Figure 1: WisBlock Unify Enclosure marked with numeralsPole Mount Vertical (Type A)
- For vertical pole mount, use two (2) pieces of mount accessories, which has an indicated mark of the letter A, as shown in Figure 14.
Figure 1: Mount accessory marked with the letter A- Fix the pole mounts marked with the letter A on the WisBlock Unify Enclosure using four (4) pieces of M3*8 mm head screw with a washer. Place it on fixed positions number 1 & 3 of the enclosure, as shown in Figure 15.
Figure 1: Fixing the pole mount on the enclosure| Size | Fix Position |
|---|---|
| Medium | 1 & 3 |
- After fixing the mounts on the enclosure, place the WisBlock Unify Enclosure onto the pole by using two (2) steel strips (65-89 mm), as shown in Figure 16.
The steel strips ONLY support 65-89 mm diameter of the pole.
Figure 1: Fixing the enclosure on the polePole Mount Overlap Horizontal (Type C)
- For horizontal pole mount overlap, use two (2) pieces of mount accessories, which has an indicated mark of the letter C, as shown in Figure 17.
Figure 1: Mount accessory marked with the letter C- Fix the pole mounts marked with the letter C on the WisBlock Unify Enclosure using four (4) pieces of M3*8 mm head screw with a washer. Place it on fixed positions between number 2 & 3 or 5 & 6 of the enclosure, in Figure 18.
Figure 1: Fixing the pole mount on the enclosure| Size | Fix Position |
|---|---|
| Medium | Between 2 & 3 or 5 & 6 |
- After fixing the mounts on the enclosure, place the WisBlock Unify Enclosure onto the pole by using two (2) steel strips (65-89 mm), as shown in Figure 19.
The steel strips ONLY support 65-89 mm diameter of the pole.
Figure 1: Fixing the enclosure on the poleWall Mount (Type D)
- For wall mount, use two (2) pieces of mount accessories with an indicator marked with the letter D, as shown in Figure 20.
Figure 1: Mount accessory marked with the letter D- Fix the wall mounts marked with the letter D on the WisBlock Unify Enclosure using four (4) pieces of M3*8 mm head screw with a washer. Place it on fixed positions number 1 & 3 or 2 & 4 of the enclosure, as shown in Figure 21.
Figure 1: Fixing the wall mount on the enclosure| Size | Fix Position |
|---|---|
| Medium | 1 & 3 or 2 & 4 |
- Lastly, follow the steps below, as also shown in Figure 22:
- Step 1: Use a Φ5 mm drill head to drill holes in the wall. Drill at least 55-60 mm in depth.
- Step 2: Plug the screw anchors into the drilled holes. You can use a hammer to plug it in. It helps the screws to have a secure fit on the wall.
- Step 3: Fix the WisBlock Unify Enclosure on the wall using two (2) pieces of ST3.5*35 mm tapping screws.
Figure 1: Fixing the enclosure on the wallBelt Clip Mount (Type E)
- For belt clip mount, use one (1) piece of mount accessory with an indicator marked with the letter E, as shown in Figure 23.
Figure 1: Mount accessory marked with the letter E- Fix the belt clip mount marked with the letter E on the WisBlock Unify Enclosure using two (2) pieces of M3*8 mm head screw with washer. Place it on fixed positions number 1 or 3 of the enclosure, as shown in Figure 24.
Figure 1: Fixing the belt clip mount on the enclosure| Size | Fix Position |
|---|---|
| Medium | 1 or 3 |
- Lastly, clip the unify enclosure on the belt directly, as shown in Figure 25.
Figure 1: Fixing the enclosure on the belt clipDIN Mount (Type F)
- For DIN mount, use two (2) pieces of mount accessories with an indicator marked with the letter F, as shown in Figure 26.
Figure 1: Mount accessory marked with the letter F- Fix the DIN mount marked with the letter F on the WisBlock Unify Enclosure using four (4) pieces of M3*8 mm head screw with the washer. Place it on fixed positions number 1 & 3 or 2 & 4 of the enclosure, as shown in Figure 27 and Figure 28.
Figure 1: Fixing the DIN mount on the enclosure's position number 1 & 3
Figure 1: Fixing the DIN mount on the enclosure's position number 2 & 4| Size | Fix Position |
|---|---|
| Medium | 1 & 3 or 2 & 4 |
- Lastly, clamp the buckle of the DIN mount kit at one end on the edge of the DIN rail, then rotate and press the enclosure to clamp the other end, as shown in Figure 29.
Figure 1: Fixing the enclosure on the DIN railMagnet Mount (Type G)
- For magnet mount, use one (1) up to two (2) pieces of mount accessories with an indicator marked with the letter G, as shown in Figure 30.
- The number of magnets to be used will depend on the weight of the device and enclosure.
Figure 1: Mount accessory marked with the letter G- Fix the magnet mount marked with the letter G on the WisBlock Unify Enclosure using one (1) to two (2) pieces of M3*8 mm head screw with washer. Place it on fixed positions number 1 & 3 of the enclosure, as shown in Figure 31.
Figure 1: Fixing the magnet mount on the enclosure| Size | Fix Position |
|---|---|
| Medium | 1 & 3 |
- Place the magnets onto the mounting, as shown in Figure 32.
Confirm the number of magnets according to the weight of the device. The medium unify enclosure supports up to 2 magnets.
- Avoid placing the enclosure too high or in an environment that vibrates, shocks, or is unstable because doing so could result in equipment damage or physical injury.
- The effect of magnet adsorption is related to the material of adsorption position, surface spraying thickness, and roughness, so it can only be used after confirming that the installation effect is not a problem. If the condition of the surface is not good, it may also affect the reliability of the magnet installation.
- When the enclosure is fixed on the desk by magnetic suction, do not push it back and forth, otherwise, the coating on the contact surface will be damaged.
- During installation, pay attention to the fixation of the external cable of the device to avoid the enclosure from falling off due to the excessive weight of the external cable, resulting in personal injury or equipment damage.
- Do not put the magnet close to a magnetic card or other products, or else the stored content of the product may be erased.
- Do not put the magnet close to a computer or other electronic equipment susceptible to the magnetic field, otherwise, it may cause electronic equipment-related failure.
Figure 1: Fixing the magnet mount on the enclosure- The magnet should be ordered separately. Consult before placing an order.
| No. | Diameter | Thickness | Material | Adsorption |
|---|---|---|---|---|
| 1 | 20 mm | 3 mm | NdFeB | 2800 Gauss (TBD) |
| 2 | 20 mm | 5 mm | NdFeB | 3100 Gauss (TBD) |
Handle with care to avoid personal injury or damage to the magnet.
- Lastly, attach the unify enclosure onto a metallic surface. Be careful not to pinch your fingers due to the high magnetism.
Figure 1: Fixing the enclosure onto the metal surfaceBelt Loop Mount (Type H)
- For belt loop mount, use two (2) pieces of mount accessories with an indicator marked with the letter H, as shown in Figure 34.
Figure 1: Mount accessory marked with the letter H- Fix the belt loop mount marked with the letter H on the WisBlock Unify Enclosure using four (4) pieces of M3*8 mm head screw with a washer. Place it on fixed positions number 1 to 4 of the enclosure, as shown in Figure 35.
Figure 1: Fixing the belt loop mount on the enclosure| Size | Fix Position |
|---|---|
| Medium | 1 - 4 |
- Lastly, thread the belt through the hole of the unify enclosure, as shown in Figure 36.
Figure 1: Fixing the enclosure on the belt threadLabel Mount (Type I)
- For label mount, use one (1) piece of mount accessory with an indicator marked with the letter I, as shown in Figure 37.
Figure 1: Mount accessory marked with the letter I- Fix the label mount marked with the letter I on the WisBlock Unify Enclosure using two (2) pieces of M3*8 mm head screw with the washer. Place it on fixed position numbers 1 to 4 of the enclosure, as shown in Figure 38.
Figure 1: Fixing the label mount on the enclosure| Size | Fix Position |
|---|---|
| Medium | 1 - 4 |
- Lastly, you can paste a 30 mm x 18 mm Fillet R4 label in the label zone, as shown in Figure 39 and Figure 40.
Figure 1: Label dimension
Figure 1: Attaching the label on the enclosureHook Loop Mount (Type J)
- For hook loop mount, use one (1) piece of mount accessory with an indicator marked with the letter J, as shown in Figure 41.
Figure 1: Mount accessory marked with the letter J- Fix the hook loop mount marked with the letter J on the WisBlock Unify Enclosure using two (2) pieces of M3*8 mm head screw with washer. Place it on fixed position number 1 or 3 of the enclosure, as shown in Figure 42.
Figure 1: Fixing the hook loop mount on the enclosure| Size | Fix Position |
|---|---|
| Medium | 1 or 3 |
- Lastly, hang the unify enclosure directly on a hook.