WisBlock RAKBox-B4 Enclosure Installation Guide
Assembly List
Figure 1: Assembly listAssembly
Step 1: Fix the WisIO module with three M1.2*3 screws. For assembly method and precautions, refer to RAK5005-O Baseboard Installation Guide.
Figure 1: Attaching WisIO ModuleStep 2: Fix the WisBlock module on the plate with M2.5*4 screws.
The number of screws is related to the specific module, confirm according to the actual module.
Figure 1: Attaching WisBlock Module to the EnclosureStep 3: If N-type antenna are required, remove the plugs and replace it with the N-type antenna connector and fix it in place. The other end of the cable is plugged to the IPEX connector of the WisBlock.
Figure 1: Attaching AntennaStep 4: If the built-in antenna is used, please stick the built-in antenna on the inner wall of the enclosure, as shown in the figure below.
Figure 1: Attaching Built In AntennaStep 5: Fix the battery on the plate with cable tie or double-sided adhesive sticker, and insert the battery plug into the socket of PCB.
Figure 1: BatteryStep 6: Fix the cover with screws and fasten four decorative covers to the head of the screws to complete the installation.
Figure 1: CoverInstallation
Wall Mounting
Step 1: Use Ø6mm drill head, drill 4 holes on the wall according to the dimension of the following picture and then plug the screw anchors in the wall;
Figure 1: 4 Drill HolesStep 2: Use the tapping screws, attach the device to the wall.
Figure 1: Wall mountingPole Mounting
Step 1: Fix the installation kit on the bottom of the enclosure with four M4*8 screws;
Figure 1: Pole mounting - Installation KitStep 2: Slide the Steel band clamps through the rectangular hole of the mount kit, wrap the band clamps around the pole, lock them and then tighten the clamps using a screwdriver.
Figure 1: Pole mounting - Attaching Band ClampsProtection treatment
Seal the N-type antenna:
Step 1: Connect the N-type antenna to the connector on the enclosure and fix it tight. Clean the surface of the area to be wrapped, wrap a layer of PVC tape with 50% overlap around the connector and the about 10mm of the foot of the antenna.
Figure 1: Protection treatment - Step 1Step 2: Cut off about 50cm waterproof tape, stretch it to twice the original length, wrap three layers with 50% overlap rate, and hold the joint with hands for some time to let the tape cling to the connector and antenna.
Figure 1: Protection treatment - Step 2Step 3: Wrap three layers of PVC tape over the waterproof tape around the connector and about 10mm of the foot of the antenna with 50% overlapping rate, overlap the head and tail of the waterproof tape for 10 mm, and cut the tail with scissors.
Figure 1: Protection treatment - Step 3