RAK19013 WisBlock LiPo Solar Power Slot Module Installation Guide
The RAK19013 WisBlock LiPo Solar Power Slot Module is a power board comprising a battery connector, a solar panel connector, a reset push button, and a power connector that connects to the WisBlock Base board.
Prerequisite
Required items for RAK19013 setup include:
- RAK19013 WisBlock LiPo Solar Power Slot Module
- A compatible WisBlock Base Board with Power Slot
- A compatible WisBlock Core
- Li-Ion/LiPo battery (optional)
- Solar panel connector cable (optional)
RAK19013 Connection to WisBlock Base
The RAK19013 WisBlock LiPo Solar Power Slot Module does not provide an onboard USB connector. The only way to upload code is by using a RAK5804.
WisBlock WisConnector Installation
Attach a WisConnector
WisBlock Power modules are installed in the dedicated Power Slot of compatible WisBlock Base Boards. Secure the installed module using compatible screws to ensure a reliable mechanical connection.
Figure 1: RAK19013 mounting connection to WisBlock Base moduleDetach a WisConnector
The procedure for disassembling any type of WisBlock module is the same.
- First, remove the screws.
Figure 1: Removing screws from the WisBlock module- Once the screws are removed, check the module's silkscreen to find the correct location for applying force.
Figure 1: Detach silkscreen on the WisBlock module-
Apply even force to the marked connector area on the module PCB to detach the module from the Base Board.
Figure 1: Applying even forces on the proper location of a WisBlock module
Battery Selector
Rechargeable Battery
RAK19013 can be powered by a rechargeable Li-Ion/LiPo battery via the dedicated connectors. The matching connector for the rechargeable battery wires is a JST PHR-2 2 mm pitch female . A cable assembly for the rechargeable battery connector is also available for purchase in RAK store .
The voltage of the battery must not exceed 4.3 V.
- Batteries can cause harm if not handled properly.
- Only 3.7 V-4.2 V rechargeable LiPo batteries are supported. It is highly recommended not to use other types of batteries with the system unless you know what you are doing.
- Make sure the battery wires, both rechargeable and non-rechargeable, match the polarity on the RAK19013 board. Not all batteries have the same wiring.
Solar Panel Connection
The battery can be recharged, as well, via a small Solar Panel. The matching connector for the solar panel wires is an JST ZHR-2 1.5 mm pitch female . A cable assembly for the solar panel connector is also available for purchase in RAK store .
- Only 5 V solar panels are supported. Do not use 12 V solar panels; this will destroy the charging unit and eventually other electronic parts.
- The GND pin of the solar panel connector is located on the edge of the board. Ensure the solar panel wires match the polarity on the RAK19013 board.