RAK5801 WisBlock 4-20mA Interface Module Installation Guide
Prerequisite
The modules required before installation include:
- RAK5801 WisBlock 4-20mA Interface Board
- WisBlock Base
- Your choice of WisBlock Core
WisBlock Module Installation
Mounting Mechanism
-
Plug the RAK5801 module parallel into the baseboard's IO slot, using the outer silkscreen for alignment, and press evenly until it clicks into place (see assembly instructions).
-
Always secure the RAK5801 module with 3 x M1.2 x3 pan head screws.
Figure 1: RAK5801 mounting mechanism on a WisBlock Base moduleInstallation and Removal
RAK5801 Fast Crimping Terminal Mechanism
The RAK5801 features a fast-crimping terminal connector to simplify and ensure the wiring process on the fields. The fast-crimping terminal can support cable with a width between 20 AWG to 24 AWG. The usual stripping length is around 6 to 7 mm.
During the crimping process, you should first press down and maintain the spring head of the crimping terminal firmly, then insert the stripped cable head into the corresponding connector’s hole. Once inserted correctly, then release the spring head, and the crimping process is completed.
Figure 1: RAK5801 Sensor ConnectorDisassembling
The procedure in disassembling any type of WisBlock modules is the same.
- First, remove the screws.
Figure 1: Removing screws from the WisBlock module- Once the screws are removed, check the silkscreen of the module to find the correct location where force can be applied.
Figure 1: Finding the proper position to detach the WisBlock module- Apply even force to the module at the position of the connector to detach the module from the WisBlock Base.
Figure 1: Applying even forces on the proper location of a WisBlock moduleIf you will connect other modules to the remaining WisBlock Base slots, check on the WisBlock Pin Mapper tool for possible conflicts.
After all this setup, you can now connect the battery (optional) and USB cable to start programming your WisBlock Core.
- Batteries can cause harm if not handled properly.
- Only 3.7-4.2 V Rechargeable LiPo batteries are supported. It is highly recommended not to use other types of batteries with the system unless you know what you are doing.
- If a non-rechargeable battery is used, it has to be unplugged first before connecting the USB cable to the USB port of the board to configure the device. Not doing so might damage the battery or cause a fire.
- Only 5 V solar panels are supported. Do not use 12 V solar panels. It will destroy the charging unit and eventually other electronic parts.
- Make sure the battery wires match the polarity on the WisBlock Base board. Not all batteries have the same wiring.