RAK13004 WisBlock PWM Expander Installation Guide
Prerequisite
The modules required before installation include:
- RAK13004 WisBlock PWM Expansion Module
- Your choice of WisBlock Base
- Your choice of WisBlock Core
WisBlock Module Installation
The RAK13004 is a PWM expansion module that can be mounted to the IO slot of WisBlock Base board. It can control 16-channel PWM output, and the module uses PCA9685 from NXP which can be interfaced via I²C. RAK13004 power source can be controlled by the WisBlock Core via IO2 pin or WB_IO2 in code. This feature can be utilized for applications requiring low power requirements.
| Row/Column | Column 1 | Column 2 | Column 3 | Column 4 |
|---|---|---|---|---|
| Row 1 | CH0 | CH1 | CH14 | CH15 |
| Row 2 | CH2 | CH3 | CH12 | CH13 |
| Row 3 | CH4 | CH5 | CH10 | CH11 |
| Row 4 | CH6 | CH7 | CH8 | CH9 |
| Row 5 | GND | VCC | GND | VCC |
Select a compatible WisBlock Base and WisBlock Core according to your needs.
Figure 1: RAK13004 Connection to WisBlock Base moduleAssembling and Disassembling of WisBlock Modules
Assembling Procedure
The RAK13004 module can be mounted on the IO slot of the WisBlock Base board. Also, always secure the connection of the WisBlock module by using the compatible screws.
Figure 1: RAK13004 mounting connection to WisBlock Base moduleDisassembling
The procedure in disassembling any type of WisBlock modules is the same.
- First, remove the screws.
Figure 1: Removing screws from the WisBlock module- Once the screws are removed, check the silkscreen of the module to find the correct location where force can be applied.
Figure 1: Finding the proper position to detach the WisBlock module- Apply even force to the module at the position of the connector to detach the module from the WisBlock Base.
Figure 1: Applying even forces on the proper location of a WisBlock moduleIf you will connect other modules to the remaining WisBlock Base slots, check on the WisBlock Pin Mapper tool for possible conflicts.
After all this setup, you can now connect the battery (optional) and USB cable to start programming your WisBlock Core.
- Batteries can cause harm if not handled properly.
- Only 3.7-4.2 V Rechargeable LiPo batteries are supported. It is highly recommended not to use other types of batteries with the system unless you know what you are doing.
- If a non-rechargeable battery is used, it has to be unplugged first before connecting the USB cable to the USB port of the board to configure the device. Not doing so might damage the battery or cause a fire.
- Only 5 V solar panels are supported. Do not use 12 V solar panels. It will destroy the charging unit and eventually other electronic parts.
- Make sure the battery wires match the polarity on the WisBlock Base board. Not all batteries have the same wiring.