RAK9105U Downlink Commands and Uplink Data Format
Downlink Command Reference
The RAK9105U PowerLink - Remote Reboot Switch for LoRaWAN supports remote control through standard LoRaWAN Class C downlink commands. These commands allow you to control power outputs and configure key parameters such as uplink intervals.
Output Control Commands
| Hex Command | Description |
|---|---|
| 00 00 | Turn OFF 5 V Output (Output 3, USB-C) |
| 00 01 | Turn ON 5 V Output (Output 3, USB-C) |
| 01 00 | Turn OFF 12 V Output (Output 2, Barrel Jack) |
| 01 01 | Turn ON 12 V Output (Output 2, Barrel Jack) |
| 02 01 | Set uplink interval to 1 minute |
| 02 1E | Set uplink interval to 30 minutes |
If the connected device (e.g., gateway or router) has internal capacitors, the power-off action may take a few seconds to complete.
Uplink Interval Configuration Commands
Use these downlinks to adjust how frequently the RAK9105U sends uplink data:
| Hex Command | Description |
|---|---|
| 02 01 | Set uplink interval to 1 minute |
| 02 1E | Set uplink interval to 30 minutes |
If you need to set a specific uplink transmission period, you can execute the ATC+SENDFREQ command in the WisToolBox under ADVANCE > OPEN CONSOLE to set the uplink ATC+SENDFREQ transmission period in minutes (1-1440 minutes).
Figure 1: ATC send frequencyUplink Data Description
The RAK9105U PowerLink - Remote Reboot Switch for LoRaWAN periodically sends uplink data to the LoRaWAN network server after a successful OTAA join. In this DC-powered configuration, the uplink payload structure is simple and consistent.
Uplink Structure
When powered by a standard 9–24 VDC input, the device reports basic operational status via Port 1:
- Output status: Indicates whether Output 2 (12 V) and Output 3 (5 V) are ON or OFF
- SW version of the RAK9105U MCU
This data allows you to verify the current power output state and track firmware updates remotely.
Figure 1: End Device Packet CapturePayload Structure
The following is an example of how to interpret the payload sent via Port 1 in DC power mode.
| Port: 1 | Payload: 0369 | |||
|---|---|---|---|---|
| Data Type | Byte | Parameter | Raw Data | Parsed Data |
| U8 | 1 Byte | Output status | 3 | 5 V Output ON 12 V Output ON Data description can be found in the Output status section. |
| U8 | 1 Byte | 9105U SW version | 69 | 1.0.5 |
Output Status
| Status Code | Output 3 (5 V, USB-C) | Output 2 (12 V, Barrel Jack) |
|---|---|---|
| 0 | OFF | OFF |
| 1 | ON | OFF |
| 2 | OFF | ON |
| 3 | ON | ON |