Skip to main content

WisBlock Unify Outdoor Enclosure 100x75x38 with Solar Panel Installation Guide

Package Contents

Figure 5377: Small WisBlock Unify Enclosure package content
NumberNameQuantityMaterialColor
1Top Cover with Solar Panel1ABS UL94V-0White or Grey
2Bottom Base1ABS UL94V-0White or Grey
3Gasket1SiliconeBlack
4Screw4-6Stainless steel

Assembly Guide

1. Prepare the Lid and Gasket

First, install the rubber gasket in the groove of the top cover, as shown in Figure 2. Put the four corners of the gasket into the groove, and then press the middle gently. Ensure that the gasket is not twisted.

Before assembly, check if the gasket is installed correctly. The rubber gasket helps seal the enclosure properly and protects it from dust and water.

Figure 5378: Installing the rubber gasket

2. Choose the Internal Mounting Plate

Next is to prepare the mounting plate. There are two types of mounting plates:

  • Plain mounting plate
  • WisBlock bespoke mounting plate

Plain Mounting Plate

The plain mounting plate has no holes, except for mounting holes to the enclosure. It is designed to be customized depending on the circuit board to be placed in the enclosure.

Figure 5379: Plain mounting plate

WisBlock Bespoke Mounting Plate

The WisBlock Bespoke Mounting Plate is designed specifically to hold WisBlock Base boards. You have to cut the excess bosses or parts with a wire cutter depending on the WisBlock Base board that you have.

The following guide shows what to cut depending on the WisBlock Base board.

NOTE

For the cutting reference, the red line is the cut-out area.

Figure 5380: Cutting-out excess parts of the WisBlock Internal mounting plate
RAK5005-O
Figure 5381: RAK5005-O WisBlock Base board cut-out area
RAK19007
Figure 5382: RAK19007 WisBlock Base board cut-out area
RAK19003
Figure 5383: RAK19003 WisBlock Base board cut-out area

3. Screw the WisBlock to Internal Mounting Plate

After cutting the Internal Mounting Plate, install the WisBlock Base board onto the Internal Mounting Plate with 2.2*5 mm self-tapping screws, as shown in Figure 8.

Figure 5384: Installing WisBlock Base board on the internal mounting plate

4. Attach the Mounting Plate to the Enclosure

Then, install the WisBlock Internal Mounting Plate to the base of the enclosure using four (4) pieces of M3*4 mm Countersunk head screws, as shown in Figure 9.

Figure 5385: Installing Internal Mounting Plate to the enclosure

5. Cover the Enclosure with a Lid

Finally, close the WisBlock Unify Enclosure with the top lid using four pieces of M3*8 mm head screw with a washer, as shown in Figure 10.

NOTE

Make sure that the solar panel wire will not be squeezed by the gasket and is properly arranged inside the enclosure with the other parts inside like the circuit board, stand-offs, screws, etc.

Figure 5386: Closing the WisBlock Unify Enclosure

Mounting Guide

After full assembly of the enclosure, the next step is to choose the right mounting accessory for your application.

Each mount accessory has a mark indicated by a capital letter, as shown in Figure 11, and each WisBlock Unify Enclosure has several fixed positions, which are indicated by a mark of numerals, as shown in Figure 12. The small-sized WisBlock Unify Enclosure has only four (4) fixed positions.

Figure 5387: Mount accessories marked with letters
Figure 5388: WisBlock Unify Enclosure marked with numerals

Pole Mount Vertical (Type A)

  1. For vertical pole mount, use two (2) pieces of mount accessories, which has an indicated mark of the letter A, as shown in Figure 13.
Figure 5389: Mount accessory marked with the letter A
  1. Fix the pole mounts marked with the letter A on the WisBlock Unify Enclosure using four (4) pieces of M3*8 mm Head screw with a washer. Place it on fixed positions number 1 & 3 of the enclosure as shown in Figure 14.
Figure 5390: Fixing the pole mount on the enclosure
SizeFix Position
Small1 & 3
  1. After fixing the mounts on the enclosure, place the WisBlock Unify Enclosure onto the pole by using two (2) steel strips (60-85 mm), as shown in Figure 15.
NOTE

The steel strips ONLY support 60-85 mm diameter of the pole.

Figure 5391: Fixing the enclosure on the pole

Wall Mount (Type D)

  1. For wall mount, use two (2) pieces of mount accessories with an indicator marked with the letter D, as shown in Figure 16.
Figure 5392: Mount accessory marked with the letter D
  1. Fix the wall mounts marked with the letter D on the WisBlock Unify Enclosure using four (4) pieces of M3*8 mm head screw with a washer. Place it on fixed positions number 1 & 3 or 2 & 4 of the enclosure, as shown in Figure 17.
Figure 5393: Fixing the wall mount on the enclosure
SizeFix Position
Small1 & 3 or 2 & 4
  1. Lastly, follow the steps below, as also shown in Figure 18:
  • Step 1: Use a Φ5 mm drill head to drill holes in the wall. Drill at least 55-60 mm in depth.
  • Step 2: Plug the screw anchors into the drilled holes. You can use a hammer to plug it in. It helps the screws to have a secure fit on the wall.
  • Step 3: Fix the WisBlock Unify Enclosure on the wall using two (2) pieces of ST3.5*35 mm tapping screws.
Figure 5394: Fixing the enclosure on the wall

Belt Clip Mount (Type E)

  1. For belt clip mount, use one (1) piece of mount accessory with an indicator marked with the letter E, as shown in Figure 19.
Figure 5395: Mount accessory marked with the letter E
  1. Fix the belt clip mount marked with the letter E on the WisBlock Unify Enclosure using two (2) pieces of M3*8 mm Head screw with washer. Place it on fixed positions number 1 or 3 of the enclosure as shown in Figure 20.
Figure 5396: Fixing the belt clip mount on the enclosure
SizeFix Position
Small1 or 3
  1. Lastly, clip the unify enclosure on the belt directly as shown in Figure 21.
Figure 5397: Fixing the enclosure on the belt clip

DIN Mount (Type F)

  1. For DIN mount, use two (2) pieces of mount accessories with an indicator marked with the letter F, as shown in Figure 22.
Figure 5398: Mount accessory marked with the letter F
  1. Fix the DIN mount marked with the letter F on the WisBlock Unify Enclosure using four (4) pieces of M3*8 mm Head screw with the washer. Place it on fixed positions number 1 & 3 or 2 & 4 of the enclosure as shown in Figure 23 and Figure 24.
Figure 5399: Fixing the DIN mount on the enclosure's position number 1 & 3
Figure 5400: Fixing the DIN mount on the enclosure's position number 2 & 4
SizeFix Position
Small1 & 3 or 2 & 4
  1. Lastly, clamp the buckle of the DIN mount kit at one end on the edge of the DIN rail, then rotate and press the enclosure to clamp the other end as shown in Figure 25.
Figure 5401: Fixing the enclosure on the DIN rail

Magnet Mount (Type G)

  1. For magnet mount, use one (1) up to two (2) pieces of mount accessories with an indicator marked with the letter G as shown in Figure 26.
NOTE
  • The number of magnets to be used will depend on the weight of the device and enclosure.
Figure 5402: Mount accessory marked with the letter G
  1. Fix the magnet mount marked with the letter G on the WisBlock Unify Enclosure using one (1) to two (2) pieces of M3*8 mm Head screw with washer. Place it on fixed positions number 1 & 3 of the enclosure as shown in Figure 27.
Figure 5403: Fixing the magnet mount on the enclosure
SizeFix Position
Small1 & 3
  1. Place the magnets onto the mounting as shown in Figure 28.
NOTE
  • Confirm the number of magnets according to the weight of the device. The small unify enclosure supports up to 2 magnets.
warning
  • Avoid placing the enclosure too high or in an environment that vibrates, shocks, or is unstable because doing so could result in equipment damage or physical injury.
  • The effect of magnet adsorption is related to the material of adsorption position, surface spraying thickness, and roughness, so it can only be used after confirming that the installation effect is not a problem. If the surface condition of the installation position is not good, it may also affect the reliability of the magnet installation.
  • When the enclosure is fixed on the desk by magnetic suction, do not push it back and forth artificially, otherwise, the coating on the contact surface will be damaged.
  • During installation, pay attention to the fixation of the external cable of the device to avoid falling off the enclosure due to the excessive weight of the external cable, resulting in personal injury or equipment damage.
  • Do not put the magnet close to the magnetic card and other products, or else the stored content of the product may be erased.
  • Do not put the magnet close to the computer and other electronic equipment susceptible to the magnetic field, otherwise, it may cause electronic equipment-related failure.
Figure 5404: Fixing the magnet mount on the enclosure
  • The magnet should be ordered separately. Consult before placing an order.
No.DiameterThicknessMaterialAdsorption
120 mm3 mmNdFeB2800 Gauss (TBD)
220 mm5 mmNdFeB3100 Gauss (TBD)
warning

Handle with care to avoid personal injury or damage to the magnet.

  1. Lastly, attach the unify enclosure onto a metallic surface. Be careful not to pinch your fingers due to the high magnetism.
Figure 5405: Fixing the enclosure onto the metal surface

Belt Loop Mount (Type H)

  1. For belt loop mount, use two (2) pieces of mount accessories with an indicator marked with the letter H, as shown in Figure 30.
Figure 5406: Mount accessory marked with the letter H
  1. Fix the belt loop mount marked with the letter H on the WisBlock Unify Enclosure using four (4) pieces of M3*8 mm Head screw with a washer. Place it on fixed positions number 1 to 4 of the enclosure as shown in Figure 31.
Figure 5407: Fixing the belt loop mount on the enclosure
SizeFix Position
Small1 - 4
  1. Lastly, thread the belt through the hole of the unify enclosure as shown in Figure 32.
Figure 5408: Fixing the enclosure on the belt thread

Label Mount (Type I)

  1. For label mount, use one (1) piece of mount accessory with an indicator marked with the letter I, as shown in Figure 33.
Figure 5409: Mount accessory marked with the letter I
  1. Fix the label mount marked with the letter I on the WisBlock Unify Enclosure using two (2) pieces of M3*8 mm Head screw with washer. Place it on fixed position numbers 1 to 4 of the enclosure as shown in Figure 34.
Figure 5410: Fixing the label mount on the enclosure
SizeFix Position
Small1 - 4
  1. Lastly, you can paste a 30 x 18 mm Fillet R4 label in the label zone as shown in Figure 35 and Figure 36.
Figure 5411: Label dimension
Figure 5412: Attaching the label on the enclosure

Hook Loop Mount (Type J)

  1. For hook loop mount, use one (1) piece of mount accessory with an indicator marked with the letter J, as shown in Figure 37.
Figure 5413: Mount accessory marked with the letter J
  1. Fix the hook loop mount marked with the letter J on the WisBlock Unify Enclosure using two (2) pieces of M3*8 mm Head screw with washer. Place it on fixed position number 1 or 3 of the enclosure as shown in Figure 38.
Figure 5414: Fixing the hook loop mount on the enclosure
SizeFix Position
Small1 or 3
  1. Lastly, hang the unify enclosure directly on a hook.
Figure 5415: Fixing the enclosure on the hook